(18.233.111.242)
Users online: 2887    [ij] [ij] [ij] 
Email id
 

Asian Journal of Research in Chemistry
Year : 2017, Volume : 10, Issue : 2
First page : ( 179) Last page : ( 185)
Print ISSN : 0974-4169. Online ISSN : 0974-4150.
Article DOI : 10.5958/0974-4150.2017.00030.X

RP-HPLC Method Development and Validation for Simultaneous Estimation of Telmisartan and Ramipril in pure and Pharmaceutical Dosage forms

Raju Vatchavai Bhaskara1,*, Gandhi Bonthu Mohan2, Sumanth Kamatham Srinivas2, Srinivas Kolli2, Neeraja Tupakula N Venkata Lakshmi2

1Associate Professor, Sri Vasavi Institute of Pharmaceutical Sciences. Pedatadepalli, Tadepalligudem, W. G. Dt 534101

2Sri Vasavi Institute of Pharmaceutical Sciences, Pedatadepalli, Tadepalligudem-534101, Andhra Pradesh

*Corresponding Author E-mail: bhaskar_pharmaanalyst@yahoo.co.in

Online published on 17 July, 2017.

Abstract

A new, precise, accurate, rapid and simple reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the simultaneous estimation of Telmisartan (TEL) and Ramipril (RAM) in pharmaceutical formulation and in bulk. The drugs were estimated using Shiseido C18 (250 x 4.6 mm, 5μm) column. The mobile phase is 0.5% orthophosphoricacid (A), combination of acetonitrile: methanol (70: 30, v/v) (B). A: B in the ratio of (50: 50, v/v) at a flow rate of 1 ml/min was used for the separation. Detection was carried out at 210 nm. Linearity was obtained in the concentration range of 40–120 μg/ml for TEL, 5–15μg/ml for RAM with retention times of 3.218 minutes and 4.803 minutes respectively. The correlation coefficient values were found to be greater than 0.99. Precision studies showed % RSD values less than 2% for both the drugs in all the selected concentrations. The percentage recoveries of TEL and RAM are in the range of 99.91–99.97% and 99.76–99.86% respectively. The assay results of TEL and RAM are 99.91% and 99.82% respectively. The limit of detection (LOD) and limit of quantification (LOQ) were 0.01 μg/ml, 0.8 μg/ml for TEL and 0.1μg/ml, 3μg/ml for RAM respectively. The method was validated as per ICH guidelines. The proposed validated method can be successfully used for the quantitative analysis of Telmisartan (TEL) and Ramipril (RAM) in bulk and commercially available dosage form.

Top

Keywords

Telmisartan, Ramipril, RP-HPLC, Shiseido C18 column, Validation.

Top

  
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
436,506,636 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.